" Stations, transformer sub-stations, and banks of transformers must be made through metal plates buried in coke below permanent moisture level, and connection should also be made to all available underground piping systems including the lead sheath of... "
Sessional Papers - Legislature of the Province of Ontario - Стр. 16
авторы: Ontario. Legislative Assembly - 1912
Полный просмотр - Подробнее о книге

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - Страниц: 1018
...straight line as possible, and kinks, coils and sharp bends must be avoided, f. The ground connections for' Central Stations, transformer substations, and...buried in coke below permanent moisture level, and connections should also be made to all available underground piping systems. For individual transformers...
Полный просмотр - Подробнее о книге

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - Страниц: 204
...should be carried in as nearly a straight line as possible, and kinks, coils and sharp bends avoided. The ground connection for central stations, transformer sub-stations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - 1903 - Страниц: 320
...be carried in as nearly a straight line as possible, all kinks, coils and sharp bends being avoided. The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905 - Страниц: 484
...be carried in as nearly a straight line as possible, all kinks, coils and sharp bends being avoided. The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Cyclopedia of Modern Shop Practice: A Manual of Shop Practice ..., Том 3

Howard Monroe Raymond - 1906 - Страниц: 662
...The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below...connection should also be made to all available underground piping s.VsTems, including the lead sheath of underground cables. For individual transformers and building...
Полный просмотр - Подробнее о книге

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - Страниц: 528
...be carried in as nearly a straight line as possible, all kinks, coils and sharp bends being avoided. The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - Страниц: 590
...be carried in as nearly a straight line as possible, all kinks, coils and sharp bends being avoided. The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Electric Light Wiring

Charles Edwin Knox - 1907 - Страниц: 242
...the outside of a building should be in molding at all places where it is in within seven feet from the ground. /. The ground connection for Central Stations,...connection should also be made to all available underground piping systems including the lead sheath of underground cables. g. For individual transformers and...
Полный просмотр - Подробнее о книге

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - Страниц: 438
...be carried in as nearly a straight line as possible, all kinks, coils and sharp bends being avoided. The ground connection for central stations, transformer substations, and banks of transformers should be made through metal plates buried in coke below permanent moisture level, and connection should...
Полный просмотр - Подробнее о книге

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - Страниц: 352
...of a building should be in moulding at all places where it is within seven feet from the ground. f. The ground connection for Central Stations, transformer...connection should also be made to all available underground piping systems including the lead sheath of underground cables. g. For individual transformers and...